Itrademarket Priority Listed Since 2004 |
|
Multron Top Indonesia E-mail ; multrotop@yahoo.com - Hp. 0815-9321.798, 021-92982.798 Muchsen Indonesia |
|
| | |
|
| Quest AQ5000 Indoor Quality Air Monitor, Sound Level Meter, Noise Dosimeter, Gas Detection, Vibration Meter. The TSI 8520 Dustrak Aerosol Monitor |
 (Product Photo) |
| | Measured Parameters:
Carbon Dioxide:
* Detector NDIR (non-dispersive infrared)
* Range User Selectable
* 0 to 5,000 and 0 to 20,000 ppm
*
Accuracy 0 to 5,000 ppm: +/-3% of reading +/-50 ppm
*
0 to 20,000 ppm: +/-3% of reading +/-300 ppm
Temperature Influence Additional +/-0.2% of reading
+/-2 ppm for each °C
*
Resolution 1 ppm (10 ppm above 10,000 ppm)
*
Response Time 22 seconds for 63% of final value; 70 seconds for 10-90% of 4000 ppm change
Relative Humidity:
*
Detector Capacitive
*
Range 0-100% non-condensing
*
Accuracy +/-3% @ 25°C
*
Resolution 0.1%
*
Response Time 50 seconds with min air flow of 1 mi/hr
*
(.45 meters/sec) through wand
Temperature:
*
Detector Thermistor
*
Range 0 to 60°C (+32 to +140°F)
*
Accuracy +/-5oC (+/-0.9 °F) requires min air flow of 1 mi/hr (.45 meters/sec) through wand
*
Resolution 0.1 °C
Dew Point:
*
Range -65 oC/+60 °C
*
Resolution 0.1 °C
Gas:
*
Detector O2, CO, H2S, SO2, CL2, NO2, NO, HCN & NH3
*
Resolution 0.1, 0.5 or 1 ppm depending on sensor in use
Air Velocity:
*
Detector Hot-Wire
*
Range 0-20 m/s
*
Accuracy +/- 5%
*
Resolution 0.1 m/s
Linear:
*
Range +/-1 V
*
Accuracy +/-2% of full scale
*
Resolution 0.001 Vdc
Data Storage:
*
57,344 total samples
Display:
*
20 character x 4 lines backlit LCD
Real Time Clock:
*
0.01% accuracy
Storage Rate:
*
1 sec, 1 min, 5 min, 10 min or 15 min sample or averages
Statistics Saved:
*
Up to 5 data values per sampling interval (CO2, temperature, humidity, dew point, gas and linear and air velocity input)
Communications:
*
Format RS-232, 1 start, 8 data, 1 stop bit, no parity
*
Baud Rate 1200 to 38400
Printer Output:
Summary Report includes:
*
Separate reports for each logging session indicating minimum, maximum & time of occurrence, elapsed time & average per session.
*
Gas readings include:
TWA & STEL
Time History Report Includes:
All recorded data values with date & time stamp
Power:
*
Internal Power:
"AA" Alkaline Batteries - >15 hrs @ 25°C (77°F)
*
Rechargeable NiMH Battery Pack: 7 hrs @ 25°C (77°F)
(Data Retention 30 days in the event of low battery)
*
External Power:
+6.0 Vdc output AC power adapter, 120 VAC or 240v
Environments:
*
Operating Temperature: 0 to +50°C (+32 to +122°F)
*
Storage Temperature: -20 to +60°C (-4 to +140°F)
Size:
*
Enclosure Size 3.6 x 7.1 x 1.3" (9.1 x 18.0 x 3.3 cm)
*
Wand Size 11.8" (30cm) long, 1" (2.54 cm) diameter
Weight:
*
2 lbs. (0.83 kg) | | |
|
Your inquiry will be recorded in "Member Trade Mail". |
Recommend to your friends |
|
| Company Contact |
| Name: |
Mr. Muchsen T [Marketing] |
| E-mail: |
Send Message |
| Mobile Number: |
+628159321798 |
| Phone Number: |
62.815.9321.798, 021-92982.798 |
| Fax Number: |
021- 55 44 728 |
| Address: |
Jl. Nirmala I Blok M-XI No. 4 Tangerang 15148, Jakarta Indonesia |
|