Priority Member Itrademarket Priority
Listed Since 2004
E-mail; multrotop@ yahoo.com - Hp. 0815-9321.798- Muchsen - Multron Top Indonesia - Laboratory Supplies & General Trading Tel 021-92982798 Fax. + 6221- 5544863
http://multronetopindonesia.itrademarket.com
Home Company Info Trade Offers Contact Us Recommend Us
Company Contact
Name:Mr. Muchsen
[Marketing]
E-mail: Send Message
Instant Messaging
Y!: multrotop@yahoo.com Y!: multrotop
Phone Number: 0815.9321-798, 021-92982.798
Mobile Number: +628159321798
Fax Number: 021- 55 44 863
Address: Jl. Mulia Blok M-X No.9, Cipondoh Makmur
Tangerang - Banten 15148, Jakarta
Indonesia

Write a review

Average User Review
There is no review for this company

Language: English Indonesia


 Indoor Quality Air Monitor Quest AQ5000 , Integrating Sound Level Meter, Noise Dosimeter, Gas Detection, Heat Stress Monitor, Human Vibration Meter, TSI 8520 Dustrak Aerosol Monitor, Shimpo Tachometer, Leak Pipe & Locator
Measured Parameters:
Carbon Dioxide:

* Detector NDIR ( non-dispersive infrared)
* Range User Selectable
* 0 to 5, 000 and 0 to 20, 000 ppm
*

Accuracy 0 to 5, 000 ppm: + / -3% of reading + / -50 ppm
*

0 to 20, 000 ppm: + / -3% of reading + / -300 ppm
Temperature Influence Additional + / -0.2% of reading
+ / -2 ppm for each ° C
*

Resolution 1 ppm ( 10 ppm above 10, 000 ppm)
*

Response Time 22 seconds for 63% of final value; 70 seconds for 10-90% of 4000 ppm change

Relative Humidity:

*

Detector Capacitive
*

Range 0-100% non-condensing
*

Accuracy + / -3% @ 25° C
*

Resolution 0.1%
*

Response Time 50 seconds with min air flow of 1 mi/ hr
*

( .45 meters/ sec) through wand

Temperature:

*

Detector Thermistor
*

Range 0 to 60° C ( + 32 to + 140° F)
*

Accuracy + / -5oC ( + / -0.9 ° F) requires min air flow of 1 mi/ hr ( .45 meters/ sec) through wand
*

Resolution 0.1 ° C

Dew Point:

*

Range -65 oC/ + 60 ° C
*

Resolution 0.1 ° C

Gas:

*

Detector O2, CO, H2S, SO2, CL2, NO2, NO, HCN & NH3
*

Resolution 0.1, 0.5 or 1 ppm depending on sensor in use

Air Velocity:

*

Detector Hot-Wire
*

Range 0-20 m/ s
*

Accuracy + / - 5%
*

Resolution 0.1 m/ s

Linear:

*

Range + / -1 V
*

Accuracy + / -2% of full scale
*

Resolution 0.001 Vdc

Data Storage:

*

57, 344 total samples

Display:

*

20 character x 4 lines backlit LCD

Real Time Clock:

*

0.01% accuracy

Storage Rate:

*

1 sec, 1 min, 5 min, 10 min or 15 min sample or averages

Statistics Saved:

*

Up to 5 data values per sampling interval ( CO2, temperature, humidity, dew point, gas and linear and air velocity input)

Communications:

*

Format RS-232, 1 start, 8 data, 1 stop bit, no parity
*

Baud Rate 1200 to 38400

Printer Output:

Summary Report includes:

*

Separate reports for each logging session indicating minimum, maximum & time of occurrence, elapsed time & average per session.
*

Gas readings include:
TWA & STEL
Time History Report Includes:
All recorded data values with date & time stamp

Power:

*

Internal Power:
" AA" Alkaline Batteries - > 15 hrs @ 25° C ( 77° F)
*

Rechargeable NiMH Battery Pack: 7 hrs @ 25° C ( 77° F)
( Data Retention 30 days in the event of low battery)
*

External Power:
+ 6.0 Vdc output AC power adapter, 120 VAC or 240v

Environments:

*

Operating Temperature: 0 to + 50° C ( + 32 to + 122° F)
*

Storage Temperature: -20 to + 60° C ( -4 to + 140° F)

Size:

*

Enclosure Size 3.6 x 7.1 x 1.3" ( 9.1 x 18.0 x 3.3 cm)
*

Wand Size 11.8" ( 30cm) long, 1" ( 2.54 cm) diameter

Weight:

*

2 lbs. ( 0.83 kg)


Origin:United States